Infrastructure (DOT) Corrosion Control & Protection

Foxfire Matrix Pro iDOT (TM) 100% VOC/solvent free tested and proven surface applied treatment for green or aged HIGH PSI concrete pavement surfaces. Foxfire Matrix Pro iDOT (TM) is a fast acting formula that will penetrate deep and react with free calcium hydroxide while internally harden, densify, strengthen, cure, and rapidly reduce soluble chlorides.

Bridge Deck Restoration & Polymer-Modified Overlay

Bridge deck preservation and life extension is important for todays aged infrastructure where we see extreme environmental service life acceleration factors effecting concrete pavement’s long-term durability. Foxfire Matrix Pro iDOT (TM) will enhance bond strength of ANY polymer-modified overlay, repair mortar, or sealant material on your project. FMP iDOT is a proven performer under toppings across various applications and simple to apply. Foxfire Matrix Pro iDOT (TM)is your first line of defense for internally protecting high PSI concrete pavements whether applied stand-alone, under repair details, or under polymer-modified overlays.

Advanced integral protection against:

  • Heavy wind-driven rain
  • Freeze-thaw cycles
  • Wetting/drying cycles
  • Extreme coastal marine environments
  • Stress-induced crack formation
  • Progressive rise in atmospheric CO2 levels

Concrete Pavement Durability Parameters Addressed: Liquids & Gases

Where to apply: Pretreat and prevent Chloride and de-icing intrusion damage.

  • ASTM C1556 – Standard test method for determining the apparent chloride diffusion coefficient of cementitious mixtures by bulk diffusion
  • ASTM C1152 – Standard test method for acid-soluble chloride in mortar and concrete.
  • ASTM C1218 – Standard test for method for water-soluble chloride in mortar and concrete.
  • AASHTO T365 – Standard test method for quantifying calcium oxychloride amounts in cement paste exposed to de-icing salts.

What We Learned

Use of Foxfire Matrix Pro reduced Calcium Oxychloride 60% in samples tested.

Over 30% reduction of Soluble Chlorides at the surface.

Over 70% reduction in Water Soluble Diffusion Coefficient.

  • Commercial Parking Garages
  • Commercial Store Fronts
  • Buildings with reinforced embedded steel (Marine Environments)
  • Highway On and Off Ramps
  • Public Street Intersections
  • Commercial Parking Garages
  • Commercial Store Fronts
  • Buildings with reinforced embedded steel (Marine Environments)
  • Highway On and Off Ramps
  • Public Street Intersections